For optimal performance with our AFM systems please request a quote from Park Systems. Mounted cantilevers are additionally tested. All probes that are not listed here from Adama Innovations, Applied Nano Structures, Inc, BudgetSensors, MikroMasch, Nanosensors™, Nanotools GmbH, Nanoworld AG, NuNano, Olympus Corp., are possible to order from our probe store. Probes from other manufacturers also can be possible to order upon request for quotation. The performance of probes ordered from other sources are not guaranteed.
Probe | Force Constant (N/m) | Frequency (kHz ) | Manufacture | Short Description | Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
BL-AC40TS | 0.09 | 110 | Olympus | ▪ Cantilever for imaging soft samples ▪ Backside reflective coating (Au) BioLever Mini |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-DB | 0.48 0.06 |
67 17 |
Nanoworld | ▪ Contact cantilever made of Silicon Nitride ▪ Backside reflex coating (Au) ▪ 2 cantilevers on a chip |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Pyrex-Nitride probes have silicon nitride cantilevers witd very low force constants and integrated oxide sharpened, pyramidal tips witd a height of 3.5 µm. The tip is located 4 µm behind tde free end of tde cantilever. This probe series features a support chip tdat is made of Pyrex. Two chip versions are available: The DB series witd rectangular / diving board cantilevers and tde TR series having triangular cantilevers. Botd sides of tde chip have identical cantilevers.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
PNP-TR | 0.32 0.08 |
67 17 |
Nanoworld | ▪ Contact cantilever made of Silicon Nitride ▪ Backside reflex coating (Au) ▪ 2 triangular cantilevers on a chip |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
The Pyrex-Nitride probes have silicon nitride cantilevers witd very low force constants and integrated oxide sharpened, pyramidal tips witd a height of 3.5 µm. The tip is located 4 µm behind tde free end of tde cantilever. The probe series features a support chip tdat is made of Pyrex. The TR series features two different triangular cantilevers. Botd sides of tde chip have identical cantilevers.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
DNP-S | 0.175 0.06 0.12 0.03 |
50 16 40 12 |
Bruker | ▪ Contact cantilever for imaging biological samples ▪ 4 triangular cantilevers on a chip |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Premium Contact Mode or Fluid TappingMode imaging and force measurement probes, sharpened for higher-resolution. Unmounted for BioScope / Dimension AFMs.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
NSC36/Cr-Au | 1 2 0.6 |
90 130 65 |
Mikromasch | ▪ Cantilever for EFM/KPFM and bio application ▪ Backside reflective coating (Au) ▪ Conductive tip for electrical application, coated with Cr-Au ▪ 3 cantilevers on a chip |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
QP-BioAC | 0.3 0.1 0.06 |
90 50 30 |
Nanosensors | ▪ Non-Contact cantilever with high resonant frequency ▪ Backside reflective coating (AI) ▪ 3 triangular cantilevers on a chip |
Request for Quote | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|